Wet Location Lighted Exit Signs

Lighted exit signs for wet locations mark exits and passages toward exits to guide people out of areas where the signs may be exposed to water. They mount near exit route doors and doorways and hardwire into an electrical system that keeps them lit for visibility. Signs with battery backup switch to .....Read More

Frequently Asked Questions

What are the requirements for lighted exit signs in wet locations?

Lighted exit signs in wet locations must adhere to specific requirements to ensure safety and functionality. These requirements typically include: 1. **Ingress Protection (IP) Rating**: Exit signs must have a suitable IP rating, such as IP65 or higher, to protect against water and dust ingress. This ensures the sign can withstand exposure to moisture and other environmental elements. 2. **UL Listing**: The signs should be UL 924 listed for emergency lighting and power equipment, indicating they meet safety standards for performance in wet conditions. 3. **NEMA Rating**: A NEMA 3R or higher rating is often required, indicating the enclosure is suitable for outdoor use and provides protection against rain, sleet, and external ice formation. 4. **Material and Construction**: The signs should be constructed from corrosion-resistant materials like polycarbonate or stainless steel to prevent rust and degradation over time. 5. **Sealed Enclosure**: The electrical components must be housed in a sealed enclosure to prevent water ingress, ensuring the sign remains operational during adverse weather conditions. 6. **Battery Backup**: A reliable battery backup system is essential to maintain illumination during power outages, with a minimum of 90 minutes of operation as per code requirements. 7. **Visibility and Illumination**: The signs must provide adequate illumination and visibility, even in wet conditions, to guide occupants safely to exits. This includes using LED technology for consistent brightness and energy efficiency. 8. **Installation and Mounting**: Proper installation and mounting are crucial to ensure stability and effectiveness. The signs should be securely mounted to withstand wind and other environmental forces. 9. **Compliance with Local Codes**: Adherence to local building and fire codes is mandatory, which may have additional requirements specific to the region. These requirements ensure that lighted exit signs in wet locations remain functional, visible, and safe under various environmental conditions.

How do I install a lighted exit sign for wet locations?

1. **Select the Right Sign**: Choose an exit sign rated for wet locations, ensuring it is waterproof and suitable for outdoor or damp environments. 2. **Turn Off Power**: Switch off the power supply to the circuit where the exit sign will be installed to ensure safety. 3. **Mounting the Sign**: - Determine the mounting location, ensuring visibility and compliance with local codes. - Use the provided mounting bracket or hardware to secure the sign. This may involve drilling holes and using anchors if mounting on a solid surface. 4. **Wiring the Sign**: - Open the sign’s access panel to expose the wiring compartment. - Connect the sign’s wires to the building’s electrical system. Typically, this involves connecting the black wire to the live wire, the white wire to the neutral wire, and the green or bare wire to the ground. - Use waterproof wire connectors to ensure a secure and moisture-resistant connection. 5. **Seal the Connections**: Apply silicone sealant around the wire entry points and any other openings to prevent water ingress. 6. **Install the Battery Backup**: If the sign includes a battery backup, install it according to the manufacturer’s instructions, ensuring it is properly connected and secured. 7. **Test the Sign**: - Restore power to the circuit. - Test the sign by pressing the test button to ensure it illuminates correctly and the battery backup functions. 8. **Final Adjustments**: Make any necessary adjustments to the sign’s position or alignment for optimal visibility. 9. **Compliance Check**: Ensure the installation meets local building and safety codes, including visibility and accessibility requirements.

What is the difference between battery backup and non-battery backup exit signs?

Battery backup exit signs are equipped with an internal battery that provides power to the sign in the event of a power outage. This ensures that the exit sign remains illuminated, guiding occupants to safety even when the main power supply is disrupted. These signs typically include a charging mechanism that keeps the battery charged during normal operation, and they automatically switch to battery power when needed. Battery backup exit signs are crucial for compliance with safety regulations in many buildings, as they ensure visibility during emergencies. Non-battery backup exit signs, on the other hand, rely solely on the building's electrical system for power. They do not have an internal battery and will not remain illuminated during a power failure unless connected to an emergency power source, such as a generator. These signs are generally less expensive and require less maintenance since there is no battery to monitor or replace. However, they may not meet safety codes in all jurisdictions, especially in areas where reliable emergency lighting is mandated. In summary, the primary difference lies in their power source during outages: battery backup exit signs have an internal battery for emergency illumination, while non-battery backup signs depend entirely on external power sources.

How do I choose the right material and color for exit signs to comply with local safety codes?

To choose the right material and color for exit signs that comply with local safety codes, follow these steps: 1. **Consult Local Codes**: Check local building and fire safety codes, as they dictate specific requirements for exit signs, including material and color. These codes may reference standards like the NFPA (National Fire Protection Association) or the International Building Code (IBC). 2. **Material Selection**: - **Photoluminescent**: Ideal for areas where power outages are common. They absorb light and glow in the dark. - **LED**: Energy-efficient and long-lasting, suitable for most environments. - **Incandescent**: Less common due to higher energy consumption and maintenance needs. - **Thermoplastic**: Lightweight and cost-effective, often used indoors. - **Aluminum**: Durable and suitable for outdoor or industrial settings. 3. **Color Requirements**: - **Background and Lettering**: Typically, exit signs have a red or green background with contrasting white letters, or vice versa. The choice between red and green often depends on local codes and cultural norms. - **Visibility**: Ensure high contrast between the background and lettering for maximum visibility. The letters should be at least 6 inches high with a stroke width of 0.75 inches. 4. **Illumination**: Ensure the signs are illuminated continuously, either internally or externally, to be visible in all lighting conditions. Battery backup is essential for power outages. 5. **Placement and Mounting**: Install signs at required heights and locations as specified by local codes, ensuring they are visible from all directions of approach. 6. **Consult Professionals**: Engage with architects, safety consultants, or local authorities to ensure compliance with all regulations. By adhering to these guidelines, you can select exit signs that meet safety standards and ensure the safety of building occupants.

Can lighted exit signs be used outdoors?

Yes, lighted exit signs can be used outdoors, but they must be specifically designed and rated for outdoor use. Outdoor exit signs need to be weatherproof and able to withstand various environmental conditions such as rain, wind, temperature fluctuations, and UV exposure. They should have an appropriate Ingress Protection (IP) rating, typically IP65 or higher, to ensure they are protected against dust and water ingress. Additionally, outdoor exit signs should be made of durable materials like polycarbonate or aluminum to resist corrosion and physical damage. These signs often come with features such as LED lighting for energy efficiency and long life, battery backup systems to ensure visibility during power outages, and high visibility lettering and symbols to comply with safety regulations. It's important to check local building codes and standards, such as those from the National Fire Protection Association (NFPA) or the International Building Code (IBC), to ensure compliance with specific requirements for outdoor exit signage. In summary, while standard indoor exit signs are not suitable for outdoor use, there are specially designed outdoor exit signs available that meet the necessary durability and safety standards for external environments.

How do I maintain and test lighted exit signs for wet locations?

1. **Regular Inspection**: Conduct monthly visual inspections to ensure the exit signs are intact and functioning. Check for any physical damage, water ingress, or corrosion. 2. **Cleaning**: Clean the signs regularly to remove dirt, debris, and any water stains. Use a damp cloth and mild detergent, avoiding harsh chemicals that could damage the sign. 3. **Battery Check**: Test the battery backup monthly by pressing the test button. The sign should illuminate on battery power for at least 30 seconds. Annually, perform a full 90-minute test to ensure the battery can sustain the sign during an outage. 4. **Electrical Components**: Inspect electrical connections for corrosion or damage. Ensure that all wiring is secure and that the power supply is stable. 5. **Sealing and Gaskets**: Check the integrity of seals and gaskets to prevent water ingress. Replace any damaged or worn-out seals immediately. 6. **Lighting**: Verify that all LEDs or bulbs are operational. Replace any burnt-out bulbs promptly to maintain visibility. 7. **Mounting and Positioning**: Ensure the sign is securely mounted and properly positioned for visibility. Adjust if necessary to comply with local codes and regulations. 8. **Documentation**: Keep a log of all maintenance activities, including inspections, tests, and repairs. This documentation is crucial for compliance and future reference. 9. **Professional Servicing**: Engage a qualified technician for annual servicing to perform detailed checks and maintenance beyond basic inspections. 10. **Compliance**: Ensure all maintenance and testing comply with local building codes and safety standards, such as NFPA 101 or OSHA regulations. By following these steps, you can ensure that lighted exit signs for wet locations remain functional and reliable in emergencies.

What are the best brands or models for lighted exit signs suitable for wet locations?

Sure, here are some of the best brands and models for lighted exit signs suitable for wet locations: 1. **Lithonia Lighting**: Known for their durable and reliable products, Lithonia offers models like the LHQM LED Exit Sign which is suitable for wet locations. It features a thermoplastic housing and is energy-efficient. 2. **Sure-Lites by Cooper Lighting**: The Sure-Lites WLT Series is designed for wet locations, offering robust construction and LED technology for long-lasting performance. 3. **Dual-Lite**: The EWL Series from Dual-Lite is specifically designed for wet and harsh environments. It features a corrosion-resistant housing and high-output LEDs. 4. **Beghelli**: The Aqua Series by Beghelli is engineered for wet locations, providing a waterproof design and high visibility. It is ideal for both indoor and outdoor use. 5. **Exitronix**: The VEX-WP Series is a popular choice for wet locations, offering a weatherproof design and energy-efficient LED illumination. 6. **Mule Lighting**: The WP Series from Mule Lighting is designed for wet and damp locations, featuring a rugged housing and bright LED lights. 7. **Isolite**: Known for their high-quality emergency lighting solutions, Isolite offers models like the WLE Series, which are suitable for wet locations and provide reliable performance. 8. **Emergi-Lite**: The NEMA 4X Series is designed for extreme conditions, including wet locations, offering a durable and weather-resistant design. These brands and models are recognized for their quality, durability, and compliance with safety standards, making them suitable for wet locations in various settings.